Compliance Inspections & Site Management

Certificate of Compliance inspections, infrared thermographic surveys, O&M reporting and full site management for electrical, gas and wet services.

Find the fault before it finds you.

A residential consumer unit with earth-leakage protection and every way individually labelled — main switch, stove, geyser, lights, earth leakage.

PLATE 01 · INSPECTION & CERTIFICATION

A consumer unit we installed and certified — earth leakage in place, every way labelled. A board you can read is a board the next electrician can test. Powerline installation.

The problem

Most buildings fail compliance for the same reason: nobody inspected them until something went wrong. An expired Certificate of Compliance stalls a property transfer, voids an insurance claim and leaves a landlord personally exposed. Hidden faults — a loose termination, an overloaded circuit, a leaking joint behind a wall — give warning long before they fail. You just need someone able to read the warning.

What we do

Compliance & Inspections: the scope in detail.

01

Certificate of Compliance inspection

Testing and verification of electrical, gas and plumbing installations for compliance with SANS. We inspect, test, record the results, and issue the certificate where the installation passes — or a defect list and a quote where it does not.

02

Thermographic inspection

Infrared scanning of electrical distribution, wet services and building structure to detect hidden faults — hot terminations, overloaded phases, concealed leaks, failing insulation — with a full photographic report. No downtime, no dismantling, no guesswork.

03

O&M services and reporting

Electrical and energy system reporting that states clear findings with severity ratings, then recommends a maintenance plan that extends asset performance instead of just listing problems.

04

Site management

We oversee daily operations, coordinate contractors and engineers, enforce safety protocols and manage resources to keep the project on schedule and within budget.

What you receive

Not a promise. A document.

  • Certificate of Compliance (electrical, gas or plumbing) where the installation passes
  • Photographic thermographic survey report with fault locations
  • Defect schedule with severity ratings — critical, high, moderate, monitor
  • Recommended maintenance plan with priorities and indicative costs
  • Traceable inspection record for insurers, transfer attorneys and auditors

Standards we work to

  • SANS 10142-1 — low-voltage electrical installations
  • Occupational Health and Safety Act — Electrical Installation Regulations
  • SANS 10400 — application of the National Building Regulations
  • Local authority plumbing and gas conformity requirements

Typical timeline

A residential CoC inspection is typically a single visit. Commercial and industrial inspections are scoped on site — most are completed within 2 to 5 working days, with the report issued on completion.

On site

What this looks like on a Powerline job.

Our own photographs. Nothing here is a stock image.

Inspection finding: root and stem growth forced in behind a wall-mounted meter enclosure, lifting it off the brickwork.
Close view of the same finding — dry vegetation packed into the gap between the enclosure and the wall, against the ventilation louvres.
An open distribution board showing breakers on din rail, neutral and earth bars, and the incoming cabling dressed into the enclosure.
An external gas installation: a pair of instantaneous gas water heaters with the meter between them, hard-piped, and the supply cylinders secured in a lockable cage below.

Questions

Asked often.

How long is an electrical Certificate of Compliance valid?
An electrical CoC does not expire on a fixed date, but a new certificate is required when a property is sold, and the existing certificate must be no more than two years old at transfer. Any alteration or addition to the installation also requires a new certificate for that work.
What happens if the installation fails?
You receive a defect schedule with each item rated by severity, and a quotation to repair. We can carry out the remedial work ourselves and then issue the certificate, so you are not managing two contractors and a handover between them.
Do I need a thermographic survey if I already have a CoC?
They answer different questions. A CoC confirms the installation complies today. A thermographic survey finds components that are heating up and heading for failure — the ones that cause the unplanned outage or the fire. Insurers increasingly ask for both on commercial and industrial property.
Can you inspect while the building stays operational?
Yes. Thermographic scanning is carried out under normal load with no shutdown, which is exactly why it is useful — the fault only shows when the circuit is working.

Request an inspection

Need compliance & inspections on your building?

Send the detail — building type, location and what prompted the enquiry — and we will come back with a scope, a programme and a price.

Where we are

361 9th Street, Carlswald
Midrand, 1685
Gauteng, South Africa

Service areas: Midrand · Johannesburg · Pretoria · Centurion · Sandton · Kempton Park · Gauteng

CallWhatsAppGet a quote